VAVECVisionX V4
NAME
vavec − combines the ascending aorta centerpoints
SYNOPSISvavec if=<inputvec1> ig=<inputvec2> of=<outvec>
DESCRIPTIONvavec vavec takes in both the original ascending aorta centerpoints from tracking and determines where the ascending aorta projection starts. Then it appends the centerpoints obtained from projection to the original ascending centerpoints.
Input if= is the original ascending aorta tracking centerpoints. Input ig= is the centerpoints obtained from projection. Output of= is a vector with the combined centerpoints.
OPTIONS
if= |
input vector (tracking) |
|||
ig= |
input vector (projection) |
|||
of= |
output combined vector |
vatrk(1)
AUTHORY. Xie