VSBREASTVisionX V4
NAME
vsbreast − rule-based refinement of the pectoral muscles.
SYNOPSISvsbreast if= hf= df= af= mf= zc= xc= xmin= xmax= ymax= of=
DESCRIPTION
vsbreast |
performs the rule-base refinement of the pectoral muscles. The inputs are soft tissues in the ROI, the expanded thoracic cavity and its boundary, boundary of the expanded thoracic cavity with closing fat and the distance to lung. The z coordinate of the carina, x coordinate of the sternum center, and extents of the expanded thoracic cavity are also required. The output is the newly detected pectoral muscles. |
Rules based on location and connectivity to the expanded thoracic cavity are applied to identify additional pectoral muscles that are missed by first stage region growing.
OPTIONS
if= |
input soft tissues in the ROI (byte) | ||
hf= |
input expanded thoracic cavity (byte) | ||
df= |
input 3d Euclidean distance to the lung (short) | ||
af= |
input boundary of the expanded thoracic cavity with closing fat (byte) | ||
mf= |
input boundary of the expanded thoracic cavity (byte) | ||
zc= |
input z coordinate of the carina | ||
xc= |
input x coordinate of the sternum center | ||
xmin= |
input xmin of the expanded thoracic cavity | ||
xmax= |
input xmax of the expanded thoracic cavity | ||
ymax= |
input ymax of the expanded thoracic cavity | ||
of= |
output additional pectoral muscles newly segmented |
vpbreast(1), vvbreast(1), vrbreast(1), vbreast(1)
AUTHORShuang Liu, June 2015